Hot and Cold Aisle Containment in Data Centers

Feature Hot and Cold Aisle Containment in Data Centers - AnD Cable Management Blog

Data centers are often made up of hot and cold aisles, and the design of the hot / cold aisle data center is far from new. However, the traditional setup causes warm air exhaust from one aisle to flow into the air intake of the next, meaning that the overall efficiency of the data center is impacted. And really, that’s what hot and cool aisle containment is all about.


Key Takeaways

By the end of this article, you’ll know:

  • The benefit of remote monitoring in temperature control.
  • What Hot, Cold, and Partial Aisle Containment methods are.
  • The importance of liquid cooling and airflow.
Hot and Cold Aisle Containment in Data Centers - AnD Cable Management Blog
Balancing hot and cold aisles is more important than ever to running an efficient data center

As rack density increases, especially in edge data centers and hyperscale data centers, the need for efficiency increases. This is also impacted by the fact that there are more green data centers, who may be generating their own energy using solar or other renewable resources. 

How does containment work and how does it impact your data center?

Remote Monitoring and Temperature Control

Of course, before we get to containment itself, it’s a good reminder to revisit physical layer monitoring. To know how effective any containment effort is, it’s necessary to monitor temperatures. This is most often done with temperature indicating panels, three per rack at the top, middle, and bottom, so that intake temperatures can be monitored regularly.

Of course, someone entering the area to manually check temperatures is yet another disruption to airflow, so remote monitoring as a part of physical network security is essential. This allows managers not only to monitor these temperatures, but receive alerts and take action if something goes wrong. 

A150 Remote Physical Layer Network Security Monitoring Elements
The A150 Remote Physical Layer Remote Monitoring system tracks temperature among many other elements that reduce risk and increase efficiency in data centers

But the most important fact for this discussion is to know what temperatures are so that efficiency and the effectiveness of containment can be monitored.

What is Aisle Containment?

Aisle containment is essentially isolating aisles by relative temperature. Essentially it means placing doors at the end of each aisle, and then adding panels, or barriers, from the top of the cabinet upwards. 

The more airtight this containment is, the more efficient cooling can be, and the easier it is to manage airflow. It’s pretty simple, but there are a couple of different approaches, each with its own pros and cons.

Hot vs. Cold Aisle Containment

There are two ways to manage aisle containment: hot and cold aisle containment. And they work exactly the way they sound.

  • Hot Aisle Containment: Hot aisles are contained, leaving the rest of the room at a more comfortable cool aisle temperature. It’s also easier to manage in many cases.
  • Cold Aisle Containment: Cold aisles are isolated or contained, which means the rest of the room stays at the warmer hot aisle temperature. This can also make getting the right amount of airflow tricky due to pressure changes, but managed properly it can deliver the most uniform temperature air to servers.. 

Choosing the right type of aisle containment for your data center depends on your situation, but there are some differences between new data center construction and retrofitting an existing data center.

Retrofitting vs. New Data Center Construction

In the case of a new data center, most of the time hot aisle containment is the method of choice. This is easier to set up in a new data center, as that allows you to start with the type of containment you need, and to set up HVAC systems and sensors to accommodate that. 

This creates an easier environment for technicians to work in when necessary, and is overall a more efficient choice. However, things are different when it comes to existing data centers

Existing data centers are easier to retrofit with cool aisle containment. While there is some additional monitoring, the way cooling systems work simply means this process is simpler in a currently operating system without creating expensive downtime for making moves and changes and installing containment. 

That doesn’t mean that no new data center will be built with cool aisle containment. It simply means that hot aisle containment is a more frequent choice. 

Partial Containment Solutions

When it comes to retrofitting, sometimes full aisle containment in either format is not possible. In those cases, partial containment is a solution. How is this achieved?

Often plastic strips can be used, similar to those you would go through walking into an industrial freezer or even certain restaurant kitchens. These can be hung at the end of aisles and from the tops of servers to the ceiling, just like other containment methods.

While not as effective, partial containment can be easy to retrofit and implement, and in some cases is about 75% as effective as full containment. For existing data centers looking for a quick and inexpensive efficiency solution, partial containment is a viable option. 

But containment is just a part of rack cooling solutions, and there are some new and exciting ones. 


WHITEPAPER – Optimizing Server Cabinet Rack Space to Maximize Efficiency and Reduce Costs

Optimizing Server Cabinet Rack Space to Maximize Efficiency and Reduce Costs FREE Guide - AnD Cable Products

Smart optimization can help you increase rack space and realize significant equipment cost savings. Read our step-by-step guide that shows you how – and how much you could save.

  • How Much Rack Space You Could Save
  • How to Optimize for Maximum Efficiency
  • Savings for New and Retrofit Installations
  • Overall Cost and Space Savings Post-Optimization

The Addition of Liquid Cooling

Data center cooling has evolved from older, inefficient systems to more contemporary ones in a relatively short period of time. However, one thing that has been around for a while but is experiencing a boom in denser, modern data centers is liquid cooling. 

Why? Well, in most cases liquid cooling is more efficient than air cooling in data centers, and when the two are used in conjunction, generally the best results can be achieved. The larger data centers get, the more power they consume, the greater the push towards a blended approach to cooling that not only saves power and is better for the environment, but prolongs the life of equipment and saves space as well. 

But even with the addition of liquid cooling, it’s all about efficient use of rack space and the airflow around them. 

It’s All About Airflow

No matter what kind of aisle containment is used, and no matter how efficient the cooling system, saving space, improving efficiency, and keeping things organized, maximizing rack space efficiency and airflow is vital.

That’s why data centers choose ZeroU racks and cable management systems. They not only help avoid the spaghetti mess and all the cable issues that can arise from it, but also help maximize airflow and save significant rack space in any system.

Whether you are retrofitting a data center or engaged in new construction, we have the rack system that’s right for you. 

Contact AnD Cable Products today for all of your cable, rack, and physical network security needs. We’d love to start a conversation about the right solution for you. 

FAQs

What is hot and cold aisle containment in a data center?

Hot and cold aisle containment is a data center design strategy that separates the hot exhaust air from equipment from the cold supply air. This is done by physically enclosing either the hot aisles or the cold aisles to prevent the mixing of air, which improves cooling efficiency and reduces energy costs.

What are the two main types of aisle containment?

The two main types are hot aisle containment and cold aisle containment. Hot aisle containment encloses the hot aisles, directing hot exhaust air directly to the cooling units. Cold aisle containment, on the other hand, encloses the cold aisles, keeping the cool air localized for the equipment intakes.

Which type of containment is better for a new data center?

For new data center builds, hot aisle containment is often preferred. It is generally easier to integrate with new HVAC systems and provides a more comfortable working environment for technicians, as the majority of the room remains at a cooler temperature.

Which type of containment is better for retrofitting an existing data center?

For existing data centers, cold aisle containment is typically the easier and more cost-effective option for a retrofit. It is a simpler process that can be implemented without significant downtime.

Can partial containment be used, and how effective is it?

Yes, partial containment is a viable solution when full containment is not feasible. This can be achieved using plastic strips or similar materials and is noted to be about 75% as effective as a full containment system.

Why is monitoring important for aisle containment?

Regardless of the containment method, remote monitoring and temperature control are crucial. They allow data center managers to assess the effectiveness of the containment efforts, identify any thermal inefficiencies, and optimize the cooling system for peak performance.

About the Author

Louis Chompff - Founder, AnD Cable Products, Rack and Cable ManagementLouis Chompff – Founder & Managing Director, AnD Cable Products
Louis established AnD Cable Products – Intelligently Designed Cable Management in 1989. Prior to this he enjoyed a 20+ year career with a leading global telecommunications company in a variety of senior data management positions. Louis is an enthusiastic inventor who designed, patented and brought to market his innovative Zero U cable management racks and Unitag cable labels, both of which have become industry-leading network cable management products. AnD Cable Products only offer products that are intelligently designed, increase efficiency, are durable and reliable, re-usable, easy to use or reduce equipment costs. He is the principal author of the Cable Management Blog, where you can find network cable management ideas, server rack cabling techniques and rack space saving tips, data center trends, latest innovations and more.
Visit https://andcable.com or shop online at https://andcable.com/shop/

Posted on

The Data Link Layer – How DAC and AOC Cables Can Work For You

Feature - The Data Link Layer - How DAC and AOC Cables Can Work For You - Cable Management Blog

As the need for data storage and speed increases, the need for hyperscale data centers has increased. So has the need for edge data centers as well. While large-scale centers serve companies like Amazon, Microsoft, and Google, other organizations are looking at smaller data centers closer to the end-user. In both cases, the data link layer of the data center is critical. Enter Direct Attach Copper (DACs) cables and Active Optical Cables (AOCs).


Key Takeaways

By the end of this article, you’ll know:

  • The purpose and application of DAC and AOC cables.
  • The advantages and Benefits of DAC and AOC cables.
  • The importance of Pre-installation Testing of DAC and AOC cables.
The Data Link Layer - How DAC and AOC Cables Can Work For You - Cable Management Blog
The data link layer of the data center is critical to ensuring your resources and used to their full potential

What is that data link layer? It’s the physical layer, the connection between servers that ensures all the computing resources are used to their full potential. The speed and integrity of these connectors can make a huge difference. 

They include Direct Attach Copper (DACs) cables, Active Optical Cables (AOCs), and fiber optic cable assemblies connected into transceivers throughout the data center. How does each one work, and why are they so critical to installation, maintenance, and deployment?

The Need for Speed

There are two aspects to the need for speed: the need for speed in shorter cables between servers, and the need for speed over longer distances. Different kinds of cables work differently in each instance. 

For example, DACs are most often used over short distances, connecting units in the same server rack. They can be active or passive – active connections are part of signal processing circuitry, and passive connections simply carry power. In the case of a DAC, the cable is made of copper rather than fiber. 


WHITEPAPER – Understanding Stranded and Solid Conductor Wiring in Modern Networks

Understanding Stranded and Solid Conductor Wiring in Modern Networks - AnD Cable Products Whitepaper

An overview of the differences between stranded and solid conductor wiring, the properties of each and the best cable type to use in a variety of typical settings.

  • Types of Stranded and Solid Conductor Wiring
  • Comparison of Electrical Properties
  • Factors Impacting Attenuation / Insertion Loss
  • Choosing the Right Cable


AOCs usually connect devices within the same row, but they cover longer distances than their copper cousins. However, they do not work in End of Row (EOR) or Middle of Row (MOR) configurations where certain types of patch panels are used. They are usually provided in fixed lengths from a few meters long to more than 100 meters. AOCs are active and include transceivers, control chips, and modules.

Both are fast, similar in speed to optic fiber cables, but that speed can be compromised by cable damage or in the case of DACs, electromagnetic interference. Both must be tested with a tool that can accept dual SFP/QSFP transceivers and generate and analyze traffic.

So how do you test them? Well, there are methods that include automation, but there are other factors to consider. 

Automation Matters

 Speed drives us to DACs and AOCs in some cases, but they can become damaged in a variety of ways. This often doesn’t even happen in the installation process, but in the shipping and handling before they even arrive at the data center. Sometimes it happens if they are stored and moved frequently. 

So the first place to test them is before installation. This ensures they are working before they are put into service. It’s easy to see how testing all cables at installation can be costly and time-consuming but not testing early can be costly later on. 

The solution is rapid, automated testing that can be done by running a test pattern where the results can be compared to a Bit Error Rate (BER) threshold. DAC and AOC cables including breakouts usually have a BER rating on their datasheets, especially when they are meant to be used with devices implementing the RS-FEC algorithm.

The tests only take a minute per cable and result in reports including a cable identifier, such as the serial number, identifying clearly any faulty equipment. 

Proper Power Planning

What’s the other advantage of DACs and AOCs? Energy savings. Point to point high-speed cables take less power and can save money, especially at scale. While DACs offer more dramatic numbers per cable, AOCs offer savings as well when multiple transceivers are replaced by cables. 

They’re not ideal for every case in every data center, but where they can be used as a key part of deployment, they can provide significant energy savings.

Living on the Edge Deployment

The other argument for DAC and AOC deployment and testing at installation exists on the edge. More Edge deployments force centers to increase speed, security, and efficiency at the same time as they minimize latency.

Opting to wait and address any connectivity issues during troubleshooting results in costly mistakes and skipping troubleshooting steps in favor of speedy repairs, sometimes those that are not necessary. Not only is this costly – cables can vary from tens of dollars to thousands but it can also lead to confusing labels and the increased probability of unplugging a live cable.

The fact that DACs and AOCs can be tested so quickly and easily at the time of installation is another great argument for their use in the data link layer. But no matter what cable configuration your data center uses, from point to point high-speed cables to other fiber and optical options, the management of that data link layer is critical to smooth data center operations.

Looking for High Speed Cables?

WD 25G SFP28 SFP+ DAC Cable - 25GBASE-CR, SFP28 to SFP28 Passive Direct Attach Copper, Twinax Cable

Ready to start optimizing your data link layer? Have questions about what cables might be right for you and your application? Whether you are deploying a brand new data center or making moves and changes, we’re here to help. Contact AnD Cable Products today for more information. We’re here to help every step of the way. 

FAQs

What is the main purpose of the data link layer?

The data link layer is crucial for efficient and reliable physical connections between servers, especially in data centers where fast data transfer and storage are essential.

What are DACs and AOCs?

DACs (Direct Attach Copper) are copper cables used for short-distance connections, typically within the same server rack. AOCs (Active Optical Cables) are designed for longer distances within a data center row.

What are the key differences between DACs and AOCs?

DACs are made of copper, can be active or passive, and are suitable for short distances. AOCs are always active, include transceivers, and are used for longer-distance connections.

Why is it important to test these cables before installation?

Testing the cables before installation can prevent costly and time-consuming issues later on. It’s recommended to use a rapid, automated testing method that compares results against a Bit Error Rate (BER) threshold.

Do these cables help with energy and cost savings?

Yes, the use of DACs and AOCs can lead to significant energy and cost savings due to their efficiency in data transfer.

About the Author

Louis Chompff - Founder, AnD Cable Products, Rack and Cable ManagementLouis Chompff – Founder & Managing Director, AnD Cable Products
Louis established AnD Cable Products – Intelligently Designed Cable Management in 1989. Prior to this he enjoyed a 20+ year career with a leading global telecommunications company in a variety of senior data management positions. Louis is an enthusiastic inventor who designed, patented and brought to market his innovative Zero U cable management racks and Unitag cable labels, both of which have become industry-leading network cable management products. AnD Cable Products only offer products that are intelligently designed, increase efficiency, are durable and reliable, re-usable, easy to use or reduce equipment costs. He is the principal author of the Cable Management Blog, where you can find network cable management ideas, server rack cabling techniques and rack space saving tips, data center trends, latest innovations and more.
Visit https://andcable.com or shop online at https://andcable.com/shop/

Posted on

Faster Polymer Plastic Cables? Not So Fast!

Faster Polymer Plastic Cables? Not So Fast - AnD Cable Management Blog

Just about a year ago a group from MIT demonstrated a polymer plastic cable the size of a human hair that could transmit data faster than copper – much faster. 

How fast? Well, they recorded speeds of more than 100 gigabits per second! So where is this new technology and where is it headed? Well, here are some answers for you.


Key Takeaways

By the end of this article, you’ll know:

  • The speed of polymer plastic cables compared to other cables.
  • How Polymer plastic cables simplify connections.
  • The future potential and current limitations of polymer plastic cables.
Faster Polymer Plastic Cables? Not So Fast - AnD Cable Management Blog
MIT demonstrated a plastic polymer cable the size of a human hair. Photo: MIT, https://news.mit.edu/2021/data-transfer-system-silicon-0224

The Need for Speed

First, perhaps we need to qualify what this speed is, and why computers and data centers need it. 

The first big deal is that these cables act like copper – they can directly connect devices without the need to reformat data. While standard fiber cables are faster, they require a converter to change light signals to electrical signals at each end of the connection. 

Of course, there are a lot of immediate uses for faster cables like these, including in data centers. Artificial intelligence applications like self-driving cars, manufacturing, and countless other applications where data provided as close to “real-time” as possible makes a huge difference. 

But of course, as with all such applications, speed is not the only factor.

Distance

At the moment in a laboratory setting, these cables are only good for short distances, not long ones. That doesn’t mean researchers are not confident in the impact these cables can have. 

Think of a polymer plastic cable that is both durable and lightweight, and can transmit terabits of data over a meter or beyond? Theoretically, this is the possibility, with the idea that such cables could replace USB and even the faster USB-C cables. 

Even at shorter lengths, such cables could be exceptionally useful for transferring data between more than one chip inside a device. The thinner fibers could be used to revolutionize these applications as well, making even smaller and more efficient devices possible. 

We Have the Power

The problem as it currently exists is that transferring data through copper cables consumes more and more power, to the point of diminishing returns, and such transfer generates heat – a lot of heat that must be dissipated and can actually cause damage to cables. 

The fiber optic alternative is not always compatible with silicon chips without the light to electronic transfer mentioned above. The idea behind polymer plastic is to save energy, generate less heat, and still allow for compact connections. 

If this is such a great idea, why is it not on the market yet?

From Laboratory To Market

To transfer such technology from the lab to the market takes a lot of work and requires some potential changes. First, the technology needs to be tested and perfected at a higher level. Since the concept has been established, other labs are now working on it as well, and this could be the fastest part of the process. 

But there is more:

  • New standards would have to be developed for IEEE, established, and agreed upon
  • Potentially, new connectors would need to be created for these cables to interface with other chips and other devices
  • The manufacture of new cables needs to be established at scale before they can become commonly used in any application.
  • A supply chain or the use of existing ones must be established to get cables from the plant to the end-user.

Does this sound like a lot? It is, but it has been done before. The question is, what do those who are building data centers – and would use these cables on a regular basis – think?

The Future is Now

“The need for speed has never been so great,” Bill Lambert, a data center engineer told us. “Ten years ago, no one would even have been talking about devices that would need this kind of speed. We would have told you we would never need that capacity.”

And he’s right. Many of the devices we now use every day, and their speeds would have been unimaginable before, let alone the amount of data we use. But the more we look at the uses for real-time data, the faster we need to get that information from one place to another. 

“It’s like the work from anywhere revolution,” he told us. “The last two years have totally changed what data transfer and speed look like, inside and outside of data centers. It’s a sure bet that the next few will revolutionize these ideas again.”

In an ever-changing field where speed and data matter more than ever, science has just begun to catch up with what we need. And we’re lucky enough to be a part of it. 

Have a question about updating the infrastructure in your current data center or want to learn more about building the infrastructure in a new one? Contact us here at AnD Cable Products. We have everything from the cable management you need to remote monitoring and more. 

We’re glad to be your partners going forward to tomorrow and beyond. 

Physical Layer Environment Network Security Monitoring and Control

A150 Physical Layer Environment Network Security Monitoring and Control System Brochure

Full visibility, network security and control of your physical layer environment. Monitor your entire hybrid cloud and IT infrastructure from a cloud-based, integrated dashboard:

  • Introducing the A150 System
  • A150 System Architecture – High-Level Overview
  • A150 System Features
  • System Controller Hardware and Specifications
  • Monitoring Controllers, Probes and Sensors

FAQs

What are polymer plastic cables?

Polymer plastic cables are a new type of data cable, developed by a group at MIT, that can transmit data faster than traditional copper cables. They are extremely thin, about the size of a human hair.

How fast are these cables?

The MIT team recorded speeds of more than 100 gigabits per second, which is significantly faster than copper cables.

What are the main advantages of these cables over copper and fiber?

  • No signal conversion: Unlike standard fiber optic cables, they can directly connect devices without needing a converter to change light signals to electrical signals.
  • Energy efficiency: They consume less power and generate less heat than copper cables, which helps save energy and prevents heat-related damage.
  • Compactness: Their thin and lightweight design makes them ideal for small, efficient devices and for use in data centers where space is a premium.

What are the current limitations of this technology?

Currently, these cables are only effective for short distances, primarily in a laboratory setting. They are not yet suitable for long-distance data transfer.

When will these cables be available on the market?

The technology is still in the “laboratory to market” phase. The process requires further testing, perfecting the technology, and establishing new standards and manufacturing processes before it can be widely used.

What applications could benefit from this new cable technology?

Faster polymer plastic cables could be used in a variety of applications, especially those requiring near real-time data transfer, such as data centers and applications for artificial intelligence like self-driving cars. They could also potentially replace USB and USB-C cables and be used for data transfer between chips inside a device.

About the Author

Louis Chompff - Founder, AnD Cable Products, Rack and Cable ManagementLouis Chompff – Founder & Managing Director, AnD Cable Products
Louis established AnD Cable Products – Intelligently Designed Cable Management in 1989. Prior to this he enjoyed a 20+ year career with a leading global telecommunications company in a variety of senior data management positions. Louis is an enthusiastic inventor who designed, patented and brought to market his innovative Zero U cable management racks and Unitag cable labels, both of which have become industry-leading network cable management products. AnD Cable Products only offer products that are intelligently designed, increase efficiency, are durable and reliable, re-usable, easy to use or reduce equipment costs. He is the principal author of the Cable Management Blog, where you can find network cable management ideas, server rack cabling techniques and rack space saving tips, data center trends, latest innovations and more.
Visit https://andcable.com or shop online at https://andcable.com/shop/

Posted on

How a Fire-Rated Power Distribution System Reduces Risk

How a Fire-Rated Power Distribution System Reduces Risk - AnD Cable Management Blog

Fires are not super common in data centers, but they do happen, and most often when they do, they are not reported (at least not in the news). Much of the reason for this is that fires are usually small and quickly contained. It is unusual for a data center to become fully engulfed. 

Even when such fires are reported on, details can be sketchy, causes, and investigations hidden behind NDA’s and are therefore difficult to learn from. While companies want to retain control over the narrative and how it impacts their reputation, the information around fires can and should be shared within the industry to prevent further similar events. And there are some things you can do now – such as remote monitoring – to keep your staff and facilities safe. 


Key Takeaways

By the end of this article, you’ll know:

  • The few key fire risks common to all data centers.
  • The importance of fire prevention and how to accomplish it in a data center.
  • The use of fire-rated busbar trunking systems and the guidelines for their testing.
Remote monitoring can help your data center keep staff and equipment safe from fire damage

The OVHCloud Incident

On 10 March 2021, near midnight local time, a fire started in the OVHCloud SBG2 data center, quickly got out of control, and even damaged two other nearby data centers. The fire started near two UPS units, one of which was worked on that same day. 

The company is considered a European alternative to the giant US cloud operators and is a key participant in the European Union’s GaiaX cloud project. Data centers serve some key functions in the French government, the UK vehicle licensing department, and others. Operations were directly impacted by the fire, although the company did have backup data centers, and quickly restored service to most customers. 

But poor design and operational practices that seem to sacrifice dependability for innovation have caused some issues, including major outages, for OVHCloud. The fire just punctuated an ongoing issue but also caused many data center operators and customers to pause and think about something probably not mentioned often enough: the risk of fire in data centers. 

What are the Fire Risks?

When broken down there are a few key fire risks common to all data centers, and most of the time they are relatively easy to mitigate.

  • Electrical Equipment – temperature changes can increase this risk, and of course, a source of risk is also backup power equipment. Generator rooms that contain gas or diesel fumes can create intense fires quickly that would be hard to fight.  
  • Cables – data center power cables are usually not enough to start a fire by themselves, but a damaged cable can release sparks or overheat and cause a small fire or thermal incident that can then spread. Proper cable management and monitoring of underfloor and overhead cabling can help prevent these events. 
  • HVAC Infrastructure – heating and cooling units present some fire danger to data centers and should be inspected often and monitored carefully. Its operation is also critical to maintaining optimal temperatures in the data center to prevent other thermal events. 
  • External Fire Sources – California wildfires. The recent blaze in Boulder. The Texas fires last year. All are examples of external fire risk to data centers, specifically those Edge data centers in less populated areas. 

Most of these can be controlled by properly managing the data center, but there are some events that can only be prepared for. Having fire suppression systems and plans in place is critical regardless of the likelihood of the danger. 

Fire Prevention Systems

Of course, the best prescription for dealing with fire is prevention. The key to this in the modern data center environment is a complete remote monitoring system. The A150 Network Monitoring System is designed specifically for data centers, IT rooms, and confidential lab operators with virtual graphics showing temperature, rack power consumption, and humidity. 

But most importantly for this topic, the system provides alerts for mission critical events like the sudden temperature changes associated with fires, smoke alarms, and sprinkler activation alerts. You can also be alerted to things like power spikes, a rise in server temperatures, or even UPS unit failures so you can make emergency repairs and mitigate fire risk before one starts. 

The reality is that anything you can do to prevent fire before it happens is preferrable than anything you can do to suppress and extinguish an active blaze. However, those are contingencies you need to prepare for. 

Fire Rated Power Distribution Systems

There are two primary principles when it comes to any fire safety plan, anywhere. They are the two P’s: prevent (which we discussed above) and protect. Part of both of these is the vital role of uninterrupted power. Enter the role of a fire-rated busbar trunking system.

These systems can be operational for a period of up to two or even three hours depending on their ratings. They’re also cased in a fire-retardant self-extinguishing resin that essentially protects the power supply itself. The idea is that this will give first responders time to extinguish the fire before it can spread.

How do you choose the right one for your data center? Well, there are established guidelines that indicate the type of fire, the duration they were tested for, how they endured water spray, such as that from sprinkler systems, and the power supply integrity in a fire situation.

Technically, they look like this: 

  • BS IEC 60331-1: 2019 – Tests for electric cables under fire conditions; circuit integrity
  • BS 8602:2013 – Method for assessment of fire integrity of cast resin busbar trunking systems for the safety-critical power distribution to life safety and firefighting systems
  • BS 6387:2013 (CWZ Protocol) – Test method for resistance to fire of cables required to maintain circuit integrity under fire conditions. Fire-resistant cables are classified by a sequence of symbols (for example, CWZ) in accordance with the fire resistance criteria they meet, the selected test temperature, and the length of the fire resistance test per BS 6387
  • NFPA 75 – Standard for the fire protection of IT equipment
  • ISO 834 – Fire resistance tests- elements of building construction
  • ATEX & IECEx – ATEX certification is given to equipment that has gone through rigorous testing outlined by European Union directives and proved safe to use in specific environments with explosive atmospheres, according to the zone/s they are certified to be used in.

The most important part of this discussion is the planning stage. It’s vital to have a disaster plan in place and address both prevention and keeping a fire from happening in the first place to protect the data center and minimize the fire’s impact. 

The more we learn from data center fires, the more likely we are to be able to prevent them going forward, and mitigate the damage in the rare event they do occur. 

Need some advice on cable management, remote monitoring, or other aspects of data center planning? Contact us – we’d love to start a conversation about how we can help you with your data center management plan. 

Physical Layer Environment Network Security Monitoring and Control

A150 Physical Layer Environment Network Security Monitoring and Control System Brochure

Full visibility, network security and control of your physical layer environment. Monitor your entire hybrid cloud and IT infrastructure from a cloud-based, integrated dashboard:

  • Introducing the A150 System
  • A150 System Architecture – High-Level Overview
  • A150 System Features
  • System Controller Hardware and Specifications
  • Monitoring Controllers, Probes and Sensors

FAQs

Why is a fire-rated power distribution system important for data centers?

A fire-rated power distribution system helps reduce the risk of fires in data centers. While fires in these facilities may not be common, they can lead to significant and costly downtime and data loss.

What are the primary fire risks in a data center?

The main fire risks come from electrical equipment, cables, HVAC infrastructure, and external sources such as wildfires.

What is the difference between fire prevention and fire protection in this context?

Fire prevention focuses on proactive measures to stop a fire from starting. This includes using remote monitoring systems to detect early signs of trouble, like sudden temperature changes or power spikes. Fire protection involves measures to protect the power supply and other critical systems after a fire has started, ensuring they remain operational.

What is a fire-rated busbar trunking system?

A fire-rated busbar trunking system is an alternative to traditional cabling for power distribution. It is encased in a fire-retardant resin and is designed to remain operational for up to three hours during a fire, helping to ensure a continuous power supply.

Are there any industry standards or guidelines for these systems?

Yes, these systems adhere to various established guidelines and certifications, including BS IEC 60331-1, NFPA 75, and ATEX.

About the Author

Louis Chompff - Founder, AnD Cable Products, Rack and Cable ManagementLouis Chompff – Founder & Managing Director, AnD Cable Products
Louis established AnD Cable Products – Intelligently Designed Cable Management in 1989. Prior to this he enjoyed a 20+ year career with a leading global telecommunications company in a variety of senior data management positions. Louis is an enthusiastic inventor who designed, patented and brought to market his innovative Zero U cable management racks and Unitag cable labels, both of which have become industry-leading network cable management products. AnD Cable Products only offer products that are intelligently designed, increase efficiency, are durable and reliable, re-usable, easy to use or reduce equipment costs. He is the principal author of the Cable Management Blog, where you can find network cable management ideas, server rack cabling techniques and rack space saving tips, data center trends, latest innovations and more.
Visit https://andcable.com or shop online at https://andcable.com/shop/

Posted on

Extreme Ultraviolet (EUV) Lithography – Keeping Moore’s Law Alive

Extreme Ultraviolet (EUV) Lithography - Keeping Moore’s Law Alive - Feature

In 1975, looking at the next decade, a guy named Gordon Moore revised his previous forecast of the number of integrated circuits in a microchip doubling every year to doubling every two years. Moore was not a prophet, nor a brilliant data analyst, but as his prediction held true, it later became known as a law. 

The law has become more of a guide, influencing the policies for research and development of the largest companies and chip manufacturers in the world. And it, and a new machine helping to keep Moore’s law alive, are what your iPhone and those robots from Boston Dynamics with the best dance moves have in common.


Key Takeaways

By the end of this article, you’ll know:

  • What Lithography is.
  • How the extreme ultraviolet lithography machines have kept Moore’s law alive.
  • The Challenges of keeping Moore’s law going into the future.
Macro photo/Shutterstock.com

Let There Be Light

First, we must understand lithography, an analogous method for making printed circuits. Technically defined, lithography is printing on a plane surface treated to repel the material being printed except where it is intended (or in the case of circuits, needed) to stick. 

The use of light for this treating and etching process is common, but one machine, built by ASML, a Dutch company that has cornered the market for etching the tiniest nanoscopic features into microchips with light, is playing a huge role in keeping Moore’s law viable. 

ASML introduced the first extreme ultraviolet (EUV) lithography machines for mass production in 2017, after decades spent mastering the technique, and the machine needed for the process is to put it mildly, massive and mind blowing. It’s expensive too, with a sticker price of around $150 million. TSMC, Samsung, and Intell are initial customers. 

Amazon Prime won’t be enough to get the massive machine delivered, unless you have 40 freight containers, three cargo planes, and 20 trucks on standby. What’s the big deal with this machine, and why does it (and it’s future children) matter?

How it Works

Think of a machine the size of a bus with 2 kilometers of cabling and over 100,000 parts. Inside are a series of nano-mirrors polished to precision that literally project extremely focused ultraviolet light into future chips to etch features that are often just a few atoms wide. That’s right, atoms. 

This means chips with components smaller (and more durable in many ways) than they have ever been. Smaller chips that are just as powerful, nano-sensors that are just as sensitive or accurate in a fraction of the space they take up now, and more will enable chips to get tinier, lighter, and more powerful than ever before. 

The Moore’s Law Limit

How small can chips get? Some think that Moore’s law is reaching the point where it is no longer viable, for three key reasons: 

  • Electrical leakage – As transistors get smaller, they at first become more efficient, but as they have reached nano-size, the transistor often can’t handle all of the electricity, and that means heat, and heat means potential damage to the transistor and maybe even the entire chip in some circumstances. Therefore, we can only decrease the size of a chip as we increase cooling power.
  • Heat – The electrical leakage and resulting heat means that one of two things must be limited: the amount of voltage or the number of the transistors in a given chip, thus limiting the power. The technology of Extreme Ultroviolet Lithography may offer some help in this area, but that remains unknown.
  • Economics – The price of this machine is just one factor. As chips get hotter and need more cooling the cost of keeping a data center at a viable temperature goes up, and that cost must be passed on to someone, generally the consumer. And businesses also want to extend the life of their equipment, ensuring it lasts as long as possible. Faster equipment with a shorter lifespan may not be as appealing to the average buyer or data center manager.

What does all this mean when we break it down?

Well, the data center of tomorrow may be a fraction of the size of those we have today. Or it may be equally as large, but able to store and deliver data at rates we can’t even imagine. Equipment, servers, remote sensors, everything may keep shrinking, to a point. But there will be a point when Moore’s law will no longer be valid or achievable, and that day may come sooner rather than later.

Are you running the data center of today, but looking forward to the data center of tomorrow? Are you interested in the latest remote monitoring and cabling solutions? Contact us at AnD Cable Products. We’d love to talk about what tomorrow looks like, and how we can help you head the right direction today. 

WHITEPAPER – Optimizing Server Cabinet Rack Space to Maximize Efficiency and Reduce Costs

Optimizing Server Cabinet Rack Space to Maximize Efficiency and Reduce Costs FREE Guide - AnD Cable Products

Smart optimization can help you increase rack space and realize significant equipment cost savings. Read our step-by-step guide that shows you how – and how much you could save.

  • How Much Rack Space You Could Save
  • How to Optimize for Maximum Efficiency
  • Savings for New and Retrofit Installations
  • Overall Cost and Space Savings Post-Optimization

FAQs

What is Moore’s Law?

Moore’s Law is a guiding principle in the chip manufacturing industry, first predicted by Gordon Moore in 1975. It states that the number of integrated circuits on a microchip will double approximately every two years. This has been a key driver for the creation of smaller, more powerful microchips over the decades.

How is Extreme Ultraviolet (EUV) Lithography related to Moore’s Law?

EUV lithography is a technology that helps keep Moore’s Law alive. It uses focused ultraviolet light to etch incredibly tiny features onto microchips, which allows for smaller and more dense transistor designs. This process enables the creation of more powerful and durable chips, continuing the trend of increasing transistor count predicted by Moore’s Law.

What makes EUV lithography so unique?

EUV lithography utilizes a highly precise process with specialized mirrors to project light and create features that are only a few atoms wide. The equipment used for this is massive and extremely expensive, with the first machines for mass production introduced by the Dutch company ASML in 2017.

Is Moore’s Law facing any challenges?

Yes, Moore’s Law is reaching its physical and economic limits. The article notes three key challenges:

  • Electrical Leakage: As transistors become smaller, they are more prone to electrical leakage, which generates heat.
  • Heat: The heat generated by electrical leakage can damage the chip and limits the number of transistors or the amount of voltage that can be included.
  • Economics: The high cost of EUV machines (around $150 million) and the increased cooling requirements for data centers add to the overall economic burden of continued scaling.

Will Moore’s Law continue indefinitely?

The article suggests that while EUV lithography helps extend Moore’s Law, there will eventually be a point where it is no longer achievable due to the physical and economic limitations mentioned. However, the technology may also lead to the development of smaller data centers and equipment as a result of its progression.

About the Author

Louis Chompff - Founder, AnD Cable Products, Rack and Cable ManagementLouis Chompff – Founder & Managing Director, AnD Cable Products
Louis established AnD Cable Products – Intelligently Designed Cable Management in 1989. Prior to this he enjoyed a 20+ year career with a leading global telecommunications company in a variety of senior data management positions. Louis is an enthusiastic inventor who designed, patented and brought to market his innovative Zero U cable management racks and Unitag cable labels, both of which have become industry-leading network cable management products. AnD Cable Products only offer products that are intelligently designed, increase efficiency, are durable and reliable, re-usable, easy to use or reduce equipment costs. He is the principal author of the Cable Management Blog, where you can find network cable management ideas, server rack cabling techniques and rack space saving tips, data center trends, latest innovations and more.
Visit https://andcable.com or shop online at https://andcable.com/shop/

Posted on

Edge Data Centers – Space and the Final Frontier

Edge of space - Edge Data Centers - Space and the Final Frontier - Cable Management Blog

Computing on the edge: it seems that everyone is doing it, from big industry to manufacturers, from ISPs to Cloud Computing centers. When you can locate computing and analytics power closer to machines connected via the IoT and other data sources, the faster you can gather data, and the more data you can store and analyze in a timely manner. For some, edge data centers seem like the final frontier for data.


Key Takeaways

By the end of this article, you’ll know:

  • The challenges faced by edge data centers.
  • The solutions for efficient space usage in edge data centers.
  • Economic impact of efficient space utilization.
Feature Edge Data Centers - Space and the Final Frontier - Cable Management Blog

This has resulted in data centers that vary in size, from the size of a very large cabinet to those contained in the space of a small shipping container. But like any journey to the edge, there are challenges and risks. There are two primary ones we will address here:

  • Temperature – Because of the small spaces edge data centers often occupy, airflow and temperature control can be tricky.
  • Space – Smaller size also means that saving space is critical, and on the flip side, can also enable more airflow and indirect cooling in a confined area.

In this way, the two primary challenges are related, and often a solution that mitigates one will also help mitigate the other. Let’s take a quick look at each of these.

Controlling the Environment on the Edge

The temperatures that edge data centers operate at are critical. And there is a huge difference between the cooling we need for a building designed to keep people comfortable, and a building designed to serve machines. Think of it this way: if someone opens the door to your office, you may feel a blast of warm or cold air, depending on the time of year. Your discomfort disappears quickly when the door closes, as the HVAC system takes over, and brings air back into the broad temperature tolerances humans can endure.

However, what happens when you go to an edge data center and open the door? The answer is, it depends on where it is. Large, brick and mortar data centers can be located in areas with minimal environmental challenges and low risk of natural disasters. But edge data centers must be located, well, where they are needed. That means in dusty and dirty environments, areas with extreme temperature fluctuations, and more.

There are really only two choices:

  • Develop and deploy equipment designed to withstand extremes, at a higher price point. A good example is cellular equipment like that developed by AT&T. However, the cost of this equipment is too high for standard edge data center deployment at scale.
  • Work with existing, readily available equipment and use unique strategies to combat environmental changes at a small scale, including using tents or shrouds for entry and exit, using handheld temperature and humidity monitors to evaluate current conditions, and developing strategic plans for unexpected events.

Another part of the solution is to use remote monitoring, AI and the IoT in edge data centers to mitigate the need for human intervention. Monitoring the health of equipment and preventing disaster in the first place is one of the keys to efficient management of edge data centers.

This is but one of the challenges data center managers face. The second is the efficient use of available space.

Saving Space

While cooling and environmental control are critical, so is the efficient use of space. This can result in increased airflow and easier HVAC solutions while also enabling more servers to be installed in the same amount of space.

This involves a few key steps:

  • Rack Selection – Whether a data center uses 23” or 19” racks, there are rack solutions that take up less space, and are also able to use better rack management options.
  • Cable Management – ZeroU horizontal cable managers makes more room for servers in a single rack, and they prevent the “spaghetti mess” that can happen in server racks, and be especially problematic in edge data centers that are more compact.
  • Compact Vertical Cable Management – 11U cable managers also save space and keep cables organized and easy to access should moves, changes, or repairs be needed.

Anything that can be done to save space in an edge data center makes facing the other challenges related to environmental control easier, but it also has another impact: an economic one. The less space you need to get the computing power you need, the more compact your data center can be. Alternatively, this can give you space to scale as needed without creating yet another data center space.

At the edge, there are always challenges, but there are also solutions. From controlling the environment in and around the data center to using the space in the most efficient way possible, with the right equipment, these obstacles can be transformed into opportunities to change not only how much data is collected and how quickly it can be acted upon, but where it happens as well.

Do you have questions about saving space in your edge data center? Are you looking for remote monitoring solutions? Then contact us here at AnD Cable. We’d love to start a conversation about how we can help you.

FAQs

What is an edge data center?

An edge data center is a computing facility located close to data sources, such as those connected by the Internet of Things (IoT), to enable faster data gathering, storage, and analysis.

What are the main challenges associated with deploying edge data centers?

The two primary challenges are managing temperature fluctuations and efficiently using space.

How can temperature challenges be addressed in edge data centers?

Temperature control can be handled in two ways: by using specialized, expensive equipment, or by using more affordable, standard equipment with strategic solutions like remote monitoring, AI, and IoT to mitigate environmental changes.

Why is space efficiency so important for edge data centers?

Saving space is critical because it improves airflow and cooling, which helps maintain equipment performance. It also allows for more servers to be installed and provides room for future expansion.

What are some solutions for effective space management in edge data centers?

Effective space management can be achieved by selecting the right racks and implementing efficient cable management solutions, such as ZeroU horizontal and 11U vertical cable managers.

About the Author

Louis Chompff - Founder, AnD Cable Products, Rack and Cable ManagementLouis Chompff – Founder & Managing Director, AnD Cable Products
Louis established AnD Cable Products – Intelligently Designed Cable Management in 1989. Prior to this he enjoyed a 20+ year career with a leading global telecommunications company in a variety of senior data management positions. Louis is an enthusiastic inventor who designed, patented and brought to market his innovative Zero U cable management racks and Unitag cable labels, both of which have become industry-leading network cable management products. AnD Cable Products only offer products that are intelligently designed, increase efficiency, are durable and reliable, re-usable, easy to use or reduce equipment costs. He is the principal author of the Cable Management Blog, where you can find network cable management ideas, server rack cabling techniques and rack space saving tips, data center trends, latest innovations and more.
Visit https://andcable.com or shop online at https://andcable.com/shop/

Posted on

7 Considerations When Choosing Fiber Optic Cable

7-Considerations-When-Choosing-Fiber-Optic-Cable-Feature-Image

Fiber optic cable has become the go-to choice for a variety of applications by data center managers. The reasons are many, including advances in cable technology that make it an even better choice. But there are several things to consider when choosing fiber optic cable to ensure it’s the right fit for the application. Here are seven of the most important ones.


Key Takeaways

By the end of this article, you’ll know:

  • The distance and interference considerations for implementing fiber.
  • The bandwidth and security considerations for implementing fiber.
  • The cable size and durability considerations for implementing fiber.

Jump to Section:

  1. Distance
  2. Interference
  3. Bandwidth
  4. Security
  5. Cable Size
  6. Cost
  7. Durability
Choosing Fiber Optic Cable - Discover 7 Considerations - Cable Management Blog
Choosing Fiber Optic Cable – Discover 7 Considerations

Distance

One of the big advantages of fiber optic cable is the loss factor: fiber only loses 3% of data over 100 meters compared to much greater losses with copper cables like CAT6 cables. While copper may be a great choice for short distances, the longer the cable needs to be, the bigger advantage to choosing fiber optic cable.

So the first factor to consider when choosing fiber optic cable is the distance the data must travel.

Interference

Fiber is fully resistant to interference from various sources like power lines, lightning storms, and even deliberate scrambling and disruption. So while the first consideration is how far the data must travel, the second consideration is where the data may travel. In data centers, whether cables are managed by running overhead or the less common instance of running through underfloor spaces, there can be sources of interference in or near that path.

This is also true in edge data centers, where everything is more compact and closer together. This is also true in modular data centers, and the right fiber cable can ensure that you can scale quickly and easily as needed. As we move toward collocation and hyper scaling, this becomes even more important.

Bandwidth

Data centers must be prepared for the future, and the bandwidth your cables can handle is a big part of that. For instance, the rise in the use of OM5 cables over OM3/4 especially in new builds is an indication that data centers are preparing for increased 5G and traffic from VR and AR applications.

This is essential to prepare for the coming 400G demands, especially in Edge data centers. As “work from home” or “work from anywhere” becomes the norm, even smaller residential data centers will be inundated with new traffic, as we saw through the COVID-19 pandemic. It seems that more companies are shifting to hybrid workforces, moving their corporate headquarters out of city center areas that are more expensive to rent, and even enabling partially or fully remote workforces.

Combine that with increases in “shopping from home” and multiple streaming devices, and speed and bandwidth are more important than ever.

Security

Of course, security is one of the top concerns for any data center. A single breach can put an entire company out of business, and result in serious issues if the data of thousands of customers is compromised. While most security issues are found in software and in the human factor (like compromised passwords) there is still a certain amount of risk in physical hardware.

However, fiber cables are difficult to compromise without the intrusion being detected, which means at the very least, using fiber cables, especially in areas where they could be potentially compromised physically, is a vital part of an overall data center security plan. Choosing the right cable in the right place can make the difference between protecting your data center’s security and digital assets, and a potentially costly data breach.

Cable Size

Over time, thinner fiber cables that carry as much data as their larger counterparts have been developed, making it practical to use fiber nearly anywhere. These thinner cables can also be bent and routed easily, saving space in your cable management systems.

Thinner cables also contribute to higher airflow and more efficient cooling, another potential area of cost savings. Fiber cables can also be bundled, organized, and labeled easily, preventing the spaghetti mess that often accumulates at the rear of server racks. Of course, this can also be prevented by having a better cable management plan in place.

In short, consider the size of cable you are using in any given area, and weigh that with other factors like distance, interference, and bandwidth.

Cost

Above, we mentioned OM5 being the future of fiber cables, but their wide adoption will come as they are produced in various lengths and sizes on a larger scale. This is because at the moment, they are produced to custom specifications. However, as OM3/4 are still viable and compatible with OM5, you can update your data center in incremental stages, and still utilize the less expensive OM3/4 cables as needed.

You’ll want to weigh cost against performance. Yes, OM5 is the best way to prepare for the future, but that can be done in cost-effective stages as your data center changes and grows. Replacing cables when you are doing moves and changes, or a new build will save you money in the long run.

Durability

Choosing fiber optic cable is easy when it comes to durability, as it’s an extremely durable cable for the most part. It is important that you evaluate where and how the cable is being used when choosing the proper cable. Where bends happen, and in an area where there may be more moves and changes than normal, you will want the most durable cable for that application.

Fiber comes in different diameters and insulation levels, and so you should be sure to choose the right one for that particular application. Evaluate several ways you can improve cable use to increase efficiency and scalability.

When choosing fiber optic cable that’s the best fit in any given application, be sure to take all of these factors into consideration. Need more information? You can check out some of the great information on our blog and in our various white papers, but if you still have questions, reach out to us. We’d love to start a conversation about how we can meet your data center cabling needs at any scale.

Ultimate Data Center Cable Labeling System

Ultimate Cable Labeling System - Epson Labelworks PX Printers and AnD Cable Products UniTag Cabel Labels
  • Maximum efficiency – our system bundle gives you everything you need, portable to where you need it
  • Industry-leading savings – both products have been designed to save you money, every time you use them
  • Clarity and transparency – printed labels ensure clarity and generous plastic cable label sizes allow for 3 lines of information
  • Positively impact uptime – combined, they make cable identification and troubleshooting quick and easy
  • Enable color cabled runs – UniTag color options align to ANSI/TIA 606-B Cable Labeling Standards
  • No-risk! Purchase with 100% confidence – both top-quality products are backed by a Lifetime Warranty
  • Download the Ultimate Cable Labeling System Brochure

FAQs

How does distance affect my choice of cable?

Fiber optic cable is ideal for long distances because it experiences very little data loss over hundreds of meters. Unlike copper cables, which lose a significant amount of data, fiber can transmit signals with only a 3% loss over 100 meters, making it more reliable for longer runs.

Are fiber optic cables resistant to interference?

Yes, one of the major benefits of fiber optic cables is their complete immunity to electromagnetic interference from sources like power lines, lightning, and radio signals. This makes them a more secure and reliable option in environments with potential interference.

What role does bandwidth play when selecting a cable?

Bandwidth is a crucial factor. With the increasing demands from technologies like 5G, VR, and AR, it’s important to choose a cable that can handle future needs. Newer cables, such as OM5, are designed to support higher bandwidth requirements and are a great way to future-proof your data center.

How does fiber optic cable improve security?

While most security breaches are software-related, fiber optic cables are physically difficult to compromise without being detected. Any attempt to tap into the cable would cause the light signal to drop, alerting you to the breach and making fiber a vital part of a comprehensive physical security plan.

Is cable size a significant consideration?

Yes, fiber optic cables are much thinner and lighter than copper cables. This can save valuable space in conduits and racks, improve airflow within a data center to aid in cooling, and make cable management much simpler.

Should I consider the cost when choosing a cable?

Cost is always a factor, and the article suggests weighing the cost against performance. It recommends updating your data center in stages. Older but still viable options like OM3/4 cables are less expensive than the latest OM5 technology, which can be custom-produced and therefore more costly.

How do I know which cable is the most durable?

The durability of a fiber optic cable depends on the specific application. It’s important to evaluate your environment. For example, if the cables are in an area with frequent changes or movement, you should choose a more durable type that can withstand wear and tear.

About the Author

Louis Chompff - Founder, AnD Cable Products, Rack and Cable ManagementLouis Chompff, Founder & Managing Director, AnD Cable Products
Louis established AnD Cable Products – Intelligently Designed Cable Management in 1989. Prior to this he enjoyed a 20+ year career with a leading global telecommunications company in a variety of senior data management positions. Louis is an enthusiastic inventor who designed, patented and brought to market his innovative Zero U cable management racks and Unitag cabel labels, both of which have become industry-leading network cable management products. AnD Cable Products only offer products that are intelligently designed, increase efficiency, are durable and reliable, re-usable, easy to use or reduce equipment costs. He is the principal author of the Cable Management Blog, where you can find network cable management ideas, server rack cabling techniques and space saving tips, data center trends, latest innovations and more.
Visit https://andcable.com or shop online https://andcable.com/shop/

Posted on

How to Prevent Data Center Downtime

Data center downtime is no joke. It can literally make the difference between a data center surviving and failing. And a new study by the Ponemon Institute shows that modern data centers and data centers at the edge are more susceptible to downtime than ever before. This is because data centers are much more complex than they ever have been. Most core data centers suffer 2.4 facility shutdowns per year, and some of those last around 138 minutes – more than two hours! Edge computing data centers experience twice as many shutdowns, but that average half the duration of core data center outages.

In addition, it is helpful to remember that although total facility failures occur with the least frequency, individual server or rack failures can also be costly, especially in Edge data centers, where every piece of equipment has some critical function.

At the outset it is also important that we define core data centers and edge data centers. Edge data centers are usually about ⅓ the size of their counterparts, although the term edge does not refer to size. Edge refers more to the data center location, generally closer to where the data center is needed to increase speed and response times, and save bandwidth.


Key Takeaways

By the end of this article, you’ll know:

  • How investment in new equipment and following best practices for data center management can prevent data center downtime.
  • How Comprehensive employee training cuts down data center downtime.
  • The importance of documenting everything and embracing redundancy.

Jump to Section:

Data Center Downtime

Conflicting Priorities

Data center managers are faced with decisions about efficiency, the transition to Net Zero carbon emissions, and avoiding redundancies whenever possible, but this also can leave them susceptible to downtime events if a problem occurs. This is illustrated by the causes of downtime: UPS battery failures, human error, equipment failures, other UPS equipment failures, and cyberattacks.

Respondents to the survey revealed that over half (54%) are not using best-practices, and that risks of data center downtime are increased because of cost concerns.

The Cost of Downtime

While cost concerns often increase the risk of downtime, the actual cost of downtime can be much greater. According to a 2014 survey by Gartner, facility downtime cost an average of nearly $5,600 per minute, or between $140,000 to over half a million dollars per hour depending on the organization size. These costs continue to rise, with more recent statistics from the Ponemon Institute survey mentioned above calculating average costs at nearly $9,000 per minute.

It’s more than just the money costs though. The real cost comes in reputation and customer service. Data centers that suffer above average downtime are much more likely to go bankrupt. Uptime is perhaps more critical than it ever has been, and customers remember problems far more easily than they remember reliable service over time.

So what do we do to prevent data center downtime?

How to Prevent Data Center Downtime

There are solutions to downtime issues, and many are known to data center managers. However, they are easier said than done. Here are a few of them:

  • Adopt best-practices – The fact that most data centers know they are not following best-practices reveals they know what to do, they are just not doing it.
  • Invest in new equipment – Equipment failures come in outdated equipment not up to the current needs of the data center. Replacing it is one of the easiest ways to reduce or eliminate downtime.
  • Improve your training – Be sure that all employees, both existing and new, are aware of best practices and what you expect of them on the job. Make training comprehensive and focus on outcomes and skills that build long-term success.
  • Improve your documentation – Your data center plans, including power, cabling, cable management plans, and others should be thoroughly documented and available to employees. If not, in the words of Captain Picard, “Make it so.”
  • Don’t fight redundancy – Redundancy is a good thing for the most part. You certainly don’t want to overdo it, but you do need to have contingency plans and equipment in case downtime does happen.

Of course, these solutions are simplified, nor are they always possible for data center managers to achieve with the resources they have available.

There is Room for Improvement

The takeaway from this data is twofold. First, data center downtime at these rates are unacceptable for most organizations. The second is that there are solutions, and there is plenty of room for improvement. Among the solutions mentioned above, there are some critical elements.

  • Redundancy – This has been preached from the beginning for both core and edge data centers, yet half of data centers have issues in this area. As a result, there is a trend toward more redundant equipment, especially at the edge, as large and small operations seek to better manage data center downtime.
  • Remote monitoring systems and AI – The other advancement that seeks to solve the issue of human error and detect equipment issues before they become a problem is remote monitoring and AI. Machine learning can help data center managers fix issues before downtime occurs, and helps them respond faster when a problem does occur.

Simply adding these two things can take data centers a long way toward greater uptime and more reliable service. After all, this is the goal of both core and edge computing.

Whether you manage an existing data center or you are considering starting one from scratch, we here at AnD Cable Products are here for you. We can help you with everything from cable and rack management to labeling systems and remote monitoring. Have questions? Contact us today. We’d love to start a conversation about your specific needs.

Physical Layer Environment Network Security Monitoring and Control

A150 Physical Layer Environment Network Security Monitoring and Control System Brochure

Full visibility, network security and control of your physical layer environment. Monitor your entire hybrid cloud and IT infrastructure from a cloud-based, integrated dashboard:

  • Introducing the A150 System
  • A150 System Architecture – High-Level Overview
  • A150 System Features
  • System Controller Hardware and Specifications
  • Monitoring Controllers, Probes and Sensors

FAQs

What is the average cost of data center downtime?

According to a recent study by the Ponemon Institute, the average cost of data center downtime is nearly $9,000 per minute.

What are the main causes of data center downtime?

The main causes of downtime include human error, outdated equipment, and a lack of proper planning and documentation.

How can data centers reduce human error?

Human error can be reduced by improving training for all employees, both new and existing, and by having thorough documentation of all data center plans.

Is redundancy important for preventing downtime?

Yes, the article emphasizes the importance of redundancy and having contingency plans and equipment to ensure service continuity.

How can new technology help prevent data center downtime?

The use of remote monitoring systems and AI can help detect and fix issues before they cause downtime and allow for faster responses when problems do occur.

About the Author

Louis Chompff - Founder, AnD Cable Products, Rack and Cable ManagementLouis Chompff, Founder & Managing Director, AnD Cable Products
Louis established AnD Cable Products – Intelligently Designed Cable Management in 1989. Prior to this he enjoyed a 20+ year career with a leading global telecommunications company in a variety of senior data management positions. Louis is an enthusiastic inventor who designed, patented and brought to market his innovative Zero U cable management racks and Unitag cabel labels, both of which have become industry-leading network cable management products. AnD Cable Products only offer products that are intelligently designed, increase efficiency, are durable and reliable, re-usable, easy to use or reduce equipment costs. He is the principal author of the Cable Management Blog, where you can find network cable management ideas, server rack cabling techniques and space saving tips, data center trends, latest innovations and more.
Visit https://andcable.com or shop online https://andcable.com/shop/

Posted on

Modular or Traditional Data Center Builds – Which is Better?

Modular or Traditional Data Center Build - Which is Better? Cable Management Blog

“The future of data centers is modular,” one popular website states. “The traditional data center is not dead,” says another. Who is right? What is the future of data centers? Is one better than the other, and if so, why?

Here are some pros and cons, and some potential answers data center managers might want to consider. 

Key Takeaways

By the end of this article, you’ll know:

  • The financial and real estate considerations when choosing between modular and traditional.
  • The deployment speed considerations between modular and traditional data centers.
  • The considerations of power usage and security when choosing between modular and traditional data centers.

Jump to Section:

Modular and Traditional Data Center

Modular vs. Traditional Data Center PUE

One of the first things we talk about with modular or traditional data centers is PUE, or Power Usage Efficiency. Most of the time, modular data centers have a lower PUE. However, there is a cost associated with that number.

Traditional data center builds often have a higher PUE initially because there is space for expansion and adding additional equipment. This can sometimes come with higher HVAC and other costs until the data center is at capacity and running at maximum efficiency. We’ll talk about that factor more in a moment. 

For modular data centers, because they are constructed with tight specifications and already at an efficient capacity per module, the PUE is lower from the start. All components are easily matched, and compact spaces are easier to control when it comes to cooling, humidity, and other factors.

What is the downside? When a brick and mortar data center is up and running at capacity and the design has been well executed, PUE levels can be similar, and it can be much simpler to make moves and changes without additional modules and construction. 

Security

As with PUE, there are two sides to this coin. The modular data center can be easier to secure, as they are more compact and self-contained. When installed behind a secure barrier with video and other surveillance measures, the physical security of a modular data center can be assured.

The flip side? Modular data centers may evolve and require additions over time, meaning the physical space will also have to be modified. Proper planning can mitigate this issue, but a traditional data center build can be easier to manage from this perspective, with security built into the construction itself, along with remote monitoring and other security features that must be handled differently with modular data centers. 

The argument over which is better can go either way, but the permanence of a traditional data center build often wins out when it comes to security discussions.

Modular vs. Traditional Real Estate

When locating a data center, we have talked about things like accessibility to a green power grid, the ability to construct your own green energy backups, and more. Real Estate that satisfies all of those requirements can be hard to find, and prices reflect that premium. 

So in this case, the more compact modular data center build has some distinct advantages. The less real estate you need, the less initial costs will be to purchase (or lease) space for the data center. This also has an impact on another factor: the cost of the build. 

Building Costs

Constructing a modular data center is much cheaper than constructing a traditional one, effectively 30% less. That is a huge number when you talk about initial costs. Combined with the lower cost of real estate, deploying a modular data center is much more efficient for those looking towards hyperscaling and co-location. 

This has been shown to be especially true as more “work from anywhere” options become available, and the need for high-speed data center capacity shifts from city centers and similar areas to residential and suburban ones.  

This leads us to our next advantage:

Deployment Speed

The time needed to construct a traditional data center is much greater than that needed to deploy a modular data center. The average data center takes 18-24 months from start to finish, but you can save around 30% of that time by going the modular data center route.

In part, this is because you avoid traditional construction delays due to bad weather, seasonal construction, and more.  

This is not to say modular deployment is better – it is simply faster. It could be argued that a traditional build will last longer and the overall construction will be of higher quality, but that is not always the case. Many modular data centers are created with a similar lifespan in mind and can last just as long as a traditional build.

So which one is better?

The bottom line when it comes to which one is better, a modular or traditional data center build, the answer is, it depends. Ask these questions:

  • How urgent is the need for this data center? 
  • Where will the data center be located? What is the costs associated with a greater holding of real estate?
  • What is the purpose of this data center? Is the need for moves and changes anticipated?
  • What kind of security is needed, and what is possible in the data center location?
  • What is the long-term plan for this data center?

The answers in your situation may vary, but as much as the traditional data center is not dead, the modular data center is on the rise, and for many situations, it’s the best option. 

No matter whether you are creating a modular data center or doing a traditional build, your rack and cable management matter, as does your labeling system and your physical layer security. At AnD Cable Products, we can help with all of these things. Give us a call today, tell us about your situation, and we’d be happy to have a conversation about how we can help. 

We’re here for all of your data center needs. 

Physical Layer Environment Network Security Monitoring and Control

A150 Physical Layer Environment Network Security Monitoring and Control System Brochure

Full visibility, network security and control of your physical layer environment. Monitor your entire hybrid cloud and IT infrastructure from a cloud-based, integrated dashboard:

  • Introducing the A150 System
  • A150 System Architecture – High-Level Overview
  • A150 System Features
  • System Controller Hardware and Specifications
  • Monitoring Controllers, Probes and Sensors

FAQs

What is the main difference between a modular and a traditional data center?

A traditional data center is a large, purpose-built facility constructed on-site over a long period. In contrast, a modular data center is built off-site in pre-fabricated modules that are later assembled on location, allowing for faster deployment and greater flexibility.

Which type of data center is more cost-effective?

Modular data centers are typically more cost-effective. They are about 30% cheaper to construct due to their prefabricated nature and require less real estate.

How do their deployment times compare?

Modular data centers have a significant advantage in terms of deployment speed. They can be deployed in a fraction of the time, saving approximately 30% of the time compared to traditional builds, which can take 18-24 months.

What about energy efficiency (PUE)?

Modular data centers generally have a lower initial Power Usage Effectiveness (PUE) because their compact, self-contained design is highly efficient from the start. Traditional data centers may have a higher PUE initially and become more efficient as they reach full capacity.

Is one more secure than the other?

Modular data centers are often easier to secure initially because they are compact and self-contained units. However, a traditional build with integrated security systems may offer more manageable, long-term security management.

Which option is better for my business?

The best choice depends on several factors, including your budget, real estate availability, timeline, and long-term expansion plans. Modular data centers are ideal for rapid deployment and situations where space is limited, while traditional builds are suited for large-scale, long-term investments.

About the Author

Louis Chompff - Founder, AnD Cable Products, Rack and Cable ManagementLouis Chompff, Founder & Managing Director, AnD Cable Products
Louis established AnD Cable Products – Intelligently Designed Cable Management in 1989. Prior to this he enjoyed a 20+ year career with a leading global telecommunications company in a variety of senior data management positions. Louis is an enthusiastic inventor who designed, patented and brought to market his innovative Zero U cable management racks and Unitag cabel labels, both of which have become industry-leading network cable management products. AnD Cable Products only offer products that are intelligently designed, increase efficiency, are durable and reliable, re-usable, easy to use or reduce equipment costs. He is the principal author of the Cable Management Blog, where you can find network cable management ideas, server rack cabling techniques and space saving tips, data center trends, latest innovations and more.
Visit https://andcable.com or shop online https://andcable.com/shop/

Posted on

4 Steps to Prepare Your Data Center for Net Zero Carbon Emissions

4 Steps to Prepare Your Data Center for Net Zero Carbon Emissions - AnD Cable Management Blog

The race to net zero carbon emissions is on – our economy and our world depend on it. The data center industry, one that tends to gobble up lots of power is at the forefront of a number of initiatives being implemented around the world. How will you prepare your data center for net zero carbon emissions? Here’s 4 steps that will get you started.


Key Takeaways

By the end of this article, you’ll know:

  • Why to make a commitment to reducing carbon footprint and decarbonization
  • How using sustainable energy sources and operating at peak efficiency cuts carbon footprint.
  • The importance of reaching net zero carbon emissions while maximizing uptime.

Jump to Section:

4 Steps to Prepare Your Data Center for Net Zero Carbon Emissions - AnD Cable Management Blog

The Situation Now

Data centers first became the focus of Greenpeace and other groups back in the mid-to-early 2010 boom. The focus at that time was on enterprise-level data centers – the big guys, in other words. The fact that data centers used lots of power became evident and so the move toward minimizing that impact grew in both urgency and popularity.

So much so that the position of Chief Sustainability Officer (CSO) grew to overtake the emerging position of Chief Security Officers. Those in charge of cybersecurity ended up having to change their title to CISO (Chief Information Security Officer) because CSO had already been widely recognized.

Since then, smaller edge computing data centers have become the new focus. With COVID hastening the transition, today, cloud computing, AI, remote monitoring and other data center management trends have now established a level of control and sustainability not previously thought possible.

Thanks in part to these technological developments, net zero carbon emissions now feels more achievable and less like the plot-line in a futuristic sci-fi flick. So, in what areas of the data center can emissions be reduced?

Step One – Make a Commitment

There are several individual measures that promote sustainability. The key is to take all of those individual components and standards and work them into an ecosystem that supports your emissions goal.

Companies and countries alike are making a commitment to reducing carbon emissions as a part of their brand. However, words are not enough, and these companies – including the largest hyperscaling data center companies in the world – are taking action. Advances are happening quickly in the area of artificial intelligence (AI), remote management and data center design. Being on the leading edge of these developments shows that your data center is part of this commitment to a “greener cloud infrastructure.”

Like most strategies, it’s only once a firm commitment at the top of the organization has been made that the necessary actions can be taken, including providing leaders with the authority to make decisions that align with the goal and that resources, responsibilities and accountabilities are allocated.

Step Two – Use Sustainable Energy Sources

Solar, wind and even hydroelectric power are all sustainable sources of power that can make dependence on coal and other carbon-intense fuels a thing of the past. Companies like Tesla and Microsoft are testing and deploying battery technology that can run data centers longer than ever before, even with no sun or wind available.

This means only using the local grid as your primary power source if sustainable energy is available 24+7. Otherwise, the data center will need to provide at least some sustainable sources of its own, like a solar or wind farm designed to directly support a data center.

Because this is expensive, only the largest, hyperscale companies with large data centers can be 100% self-sufficient. Hybrid solutions could help to bridge the gap, such as supplementing local power supplies with solar and wind on site. Selecting a site that’s close to a local, sustainable power grid should be a factor in choosing where to locate your data center and will support the goal of net zero carbon emissions.

Step Three – Operate at Peak Efficiency

For data centers, not only should your power be sourced responsibly, but your data center needs to operate efficiently. One way to reduce carbon dependency is to simply use less power. Strategies can include initiatives such as pro-active device monitoring to identify ‘Zombie Servers’ – stacks that contribute little to performance, but still use significant resources to maintain.

The efficient and responsible use of power, as covered by the United Nations Sustainable Development Goal 12, is about Responsible Production and Consumption. Some other standards include:

  • PUE (Power Use Effectiveness) – Determined by dividing the power coming into the data center by the power used by the computer infrastructure.
  • LEED (Leadership in Energy & Environmental Design) – A green building certification program that rates building design
  • PAR4 – A new form of power measurement that accurately measures IT equipment power usage to help optimally plan for capacity.
  • ASHRAE (The American Society of Heating, Refrigerating and Air-Conditioning Engineers) – Standards for the temperature and humidity operating ranges for IT equipment and data centers.
  • CCF (Cooling Capacity Factor) – CCF is a metric used to evaluate rated cooling capacity against how that capacity is actually used.

These standards are just a few of those used to rate the efficiency of a data center and are designed to help data centers move toward net zero through more effective use of the power they have available.

Step Four – Build-in Resilience and Agility

The real job of a data center is uptime. Yes, customers want a green data center that is moving toward, if not already achieving, net zero emissions. However, at the same time, they expect that there will be no reduction in service. They expect full uptime, speed, and data protection.

This means that systems must not only be green, but must be reliable and include redundancies, power backups, and other protections, including cybersecurity and physical layer security to protect both customer assets and their data.

The good news is that not only is clean energy better for the environment, but it is also more reliable in many cases, allowing data centers to keep uptime near 99.999% standards. This is a balance that sustainable data centers must constantly monitor, adjust to and plan for.

Net zero carbon emissions is the standard of the future. Your data center can prepare now. Use clean energy, and plan to scale with that energy use in mind. Use the energy you have efficiently and plan for resiliency as part of your transition strategy. It’s what clients and customers and the world deserves.

Have questions about optimizing your physical layer, monitoring and remote control or ways to use your floor space efficiently? Contact Us at AnD Cable Products. We’re here to help.

Physical Layer Environment Network Security Monitoring and Control

A150 Physical Layer Environment Network Security Monitoring and Control System Brochure

Full visibility, network security and control of your physical layer environment. Monitor your entire hybrid cloud and IT infrastructure from a cloud-based, integrated dashboard:

  • Introducing the A150 System
  • A150 System Architecture – High-Level Overview
  • A150 System Features
  • System Controller Hardware and Specifications
  • Monitoring Controllers, Probes and Sensors

FAQs

What is the first and most critical step to a more sustainable data center?

The first step is to measure energy usage. The most commonly used industry standard for this is Power Usage Effectiveness (PUE).

Why is measuring PUE important?

PUE is an individual benchmark for performance and a starting point for measuring success. It helps identify changes in power usage, trends, and spikes, enabling informed decisions for upgrades and infrastructure changes to improve sustainability.

What are the four key steps outlined in the article for preparing a data center for net-zero carbon emissions?

–Make a Commitment: Embrace individual measures that promote sustainability.

–Use Sustainable Energy Sources: Utilize sources like solar, wind, and hydroelectric power, and consider hybrid solutions.

–Operate at Peak Efficiency: Reduce power consumption by strategies such as proactive device monitoring and identifying “Zombie Servers” (servers that contribute little to performance but still use significant resources).

–Build-in Resilience and Agility: Ensure systems are not only green but also reliable, with redundancies and power backups to maintain uptime.

What is the goal of operating at peak efficiency?

The goal is to use less power. The article mentions strategies like using PUE, LEED, and PAR4 standards to rate efficiency.

About the Author

Louis Chompff - Founder, AnD Cable Products, Rack and Cable ManagementLouis Chompff, Founder & Managing Director, AnD Cable Products
Louis established AnD Cable Products – Intelligently Designed Cable Management in 1989. Prior to this he enjoyed a 20+ year career with a leading global telecommunications company in a variety of senior data management positions. Louis is an enthusiastic inventor who designed, patented and brought to market his innovative Zero U cable management racks and Unitag cabel labels, both of which have become industry-leading network cable management products. AnD Cable Products only offer products that are intelligently designed, increase efficiency, are durable and reliable, re-usable, easy to use or reduce equipment costs. He is the principal author of the Cable Management Blog, where you can find network cable management ideas, server rack cabling techniques and space saving tips, data center trends, latest innovations and more.
Visit https://andcable.com or shop online https://andcable.com/shop/